Filter Results By:

Products

Applications

Manufacturers

Showing results: 241 - 255 of 273 items found.

  • Voltage/Continuity Testers

    VOT-53 - Standard Electric Works Co., Ltd

    ● 2000-count digital display (LCD type).    ● Test leads positioned at 19mm apart.● Interchangeable probe tip for 2mm and 4mm.● Polarity test ● Audible continuity test.● Auto sensing function for: voltage (AC/DC), Ω, diode.● Measurement function:   ACV/DCV: 1000V   Resistance: 2000Ω   Frequency: 30Hz~1kHz ● Phase rotation test : ● Waterproof design, protection class: IP65.● Phase / Neutral identification.● Rubberized double-molded housing.● Flashlight function.● Safety standard :     EN 61010-1 CAT III 1000V    EN 61010-1 CAT IV 600V    EN 61243-3    EN 61326-1

  • New Battery Analyzer

    Hangzhou Xun Anda Electrical Co., Ltd.

    1. Test application: 12V/6V batteries test and 12V Starting /Charging system test.2. Test battery type: regular liquid, AGM battery, GEL battery,VRLA battery3. CCA test range: 40~2000CCA (SAE).4. Voltage test range: 1.5-15V.5. Display SOH (state of health), SOC(state of charge).6. Test for multiple battery standards: SAE, DIN, EN, IEC, CA.7. Graphic LCD display with back light, LCD brightness adjustable.8. Multigle language operation: English, Chinese, Germany, French, Spanish. 9.internal resistance

  • New Battery Conductance Tester

    Hangzhou Xun Anda Electrical Co., Ltd.

    1. Test application: 12V/6V batteries test and 12V Starting /Charging system test.2. Test battery type: regular liquid, AGM battery, GEL battery,VRLA battery3. CCA test range: 40~2000CCA (SAE).4. Voltage test range: 1.5-15V.5. Display SOH (state of health), SOC(state of charge).6. Test for multiple battery standards: SAE, DIN, EN, IEC, CA.7. Graphic LCD display with back light, LCD brightness adjustable.8. Multigle language operation: English, Chinese, Germany, French, Spanish. 9.internal resistance

  • New Car Alternator Charging Tester

    Hangzhou Xun Anda Electrical Co., Ltd.

    1. Test application: 12V/6V batteries test and 12V Starting /Charging system test.2. Test battery type: regular liquid, AGM battery, GEL battery,VRLA battery3. CCA test range: 40~2000CCA (SAE).4. Voltage test range: 1.5-15V.5. Display SOH (state of health), SOC(state of charge).6. Test for multiple battery standards: SAE, DIN, EN, IEC, CA.7. Graphic LCD display with back light, LCD brightness adjustable.8. Multigle language operation: English, Chinese, Germany, French, Spanish. 9.internal resistance

  • Electrical Safety Testers- Hipots

    Salicon Nano Technology

    Safety testers (also named hi-pot tester/hipot tester/hipot test) are designed to ensure safe operation of DUTs under various operating conditions and environment.GW Instek’s GPT-9900/GPT-9800/9600 series safety testers(hipot test) provide safe and quick measurement tools for AC/DC withstanding voltage tests, insulation resistance tests, and AC ground bond tests. Those tests are required by many international safety regulations such as CE, UL, VDE, and etc. We also have leakage current tester, GLC-9000, which supports all the major leakage current test standards for medical and general electronic equipment.

  • Power Line Purpose Tester

    LX-221A+ - Shenzhen Lian Xin Technology Co., Ltd.

    ·Meet UL, VDE, CSA, SAA, T-MARK, KS. IRAM, CCC and other countries’ standards .·Used to test single – ends ,double –ends ,three-ends power supply cords.·Auto and continuous test in COND,Insulation Resistance ,Leakage Current, Line-to-line Hi-pot(inside HV), Leaking copper(outside HV), relative length,·Auto test the fine and detective goods, tested qualified ones can be be ejected by ejector pin and marked , automatic cutting defective products, and alarmed with voice prompt and light,·Provide with RS 232 interfaces, can communicate with PC, easy to upgrade,·Provide personalized customization according to different requirements.

  • External Measurement Instrument Port | Add-On Option to CableEye HVX Series Testers

    Item 835 - CAMI Research Inc. (CableEye®)

    Measure 10 GΩ Isolation at 100 V

    This new capability is of special interest to customers requiring measurements of extremely high isolation resistance at very low voltages. The HVX-series option may be ordered with new testers or added as an upgrade to previously purchased systems. Application Applications for such high isolation measurements at very low voltage include mission critical devices with densely packed pins that would arc at higher voltages potentially causing damage: For example, the testing of military or aerospace cables with nano connectors. Exacting Reporting Standards CableEye® software allows customers to meet the most exacting reporting requirements of government-contracted and ISO 9000-style certified companies. Co-Requisites This options co-requires the 4-Wire Kelvin Resistance Measurement option (Item 832), and a third party source Source Measure Unit (SMU – Keithley Model 2410 or 2470).

  • Insulation Meters

    PCE Instruments

    Here you will find an insulation tester for a variety of ranges between 50 mega ohms and 2000 mega ohms. The portable manual insulation tester is used for determining insulation resistance, continuous current, alternating current and testing. With an insulation tester, measurements can be taken for different voltages, beginning with 100V up to 10,000V. Measurements meet the DIN VDE 0413 part 1 standard. The insulation tester comes with a test mechanism, clips, batteries and a carrying case. The insulation meter can be equipped for test laboratories if an optional DIN EN ISO is acquired.Measurement of insulation in cables and motor coils is vitally important for the prevention of accidents and damage to installations and is obligatory according to most codes of conduct.

  • Installation Safety Testers

    PeakTech Prüf- und Messtechnik GmbH

    This innovative combination meter for testing electrical installations according to VDE 0100 convinces by its technical performance in the high-end range.With the large 3.5 "TFT color display all important safety checks as the RCD-, Voltage-, Loop-, Low-Ohm, Earth resistance and Insulation tests for annual safety-checks and newly installed systems can safely be carried out by the responsible electrical engineer.Since this new development was designed only according to the latest standards, the required measuring values can be even more convenient stored with an App (iOS / Android) via Bluetooth on the mobile phone, saved to an SD card or, when work is completed, from the internal data memory via USB connection to a PC.

  • Three-Phase Transformer Winding Resistance Meters

    TWA Standard Series - IBEKO Power AB

    When it comes to winding resistance measurement on three-phase power transformers and autotransformers, TWA Standard series offers some of the most technically advanced instruments with LCD display in the market. Both models are capable of testing six transformer windings with a one-time cable connection, as well as three-phase automatic transformer demagnetization. The stored magnetic energy is safely automatically discharged at the end of the test. The built-in tap changer control unit enables automated test mode, where the instrument operates the tap changer without operator input and records winding resistance results based on pre-selected stabilization criteria. This option makes the operator’s job significantly easier.Both models can output test currents from 5 mA to 25 A DC for the purpose of winding resistance measurement. TWA40D has a special test mode for checking the synchronization of on-load tap changers with three phases simultaneously tested in parallel, in which the total test current can rise to up to 40 A DC.TWA40D has additional advantages when it comes to non-intrusive tap changer analysis. The unique DVtest method enables checking the moving contacts of on-load tap changers during the transition, measuring the transition time, detecting open circuits, and many other types of faults. It is performed with 0.1 ms sampling rate, simultaneously with the measurement of tap changer motor current which helps with the detection of motor and mechanical issues. A special proprietary algorithm is used for testing tap changers connected through a built-in series (booster) transformer. The DVtest can be performed either on one phase or on three phases simultaneously. It can also be performed as an additional test simultaneously with the winding resistance test in all tap positions.An additional unique advantage of TWA40D is the capability of simultaneously testing the winding resistance of all three phases of a three-phase transformer (connected in a YN configuration). This can significantly shorten the total testing time – for example, it enables the operator to perform 33 measurements instead of 99 on a tap changer with 33 tap positions.The test leads for TWA three-phase transformer winding ohmmeters are interchangeable with the TRT turns ratio testers, which means that both sets of tests can be performed with a single test lead connection to the power transformer terminals.

  • Battery Extra Load Units

    BXL Series - IBEKO Power AB

    BXL is an extra load unit designed to be used with DV Power’s BLU series battery testers. However, this unit is a universal add-on device. Because of that, it is compatible, as an additional load, with any other discharge/capacity tester in the market.In case when discharge current exceeds the capacity of a single BLU device, BXL can increase the discharge capacity. There are no limitations on the number of extra load units that can be connected in parallel to the main battery tester.A system of BLU and BXL instruments enables performing the capacity test in an accurate, user-friendly way. Also, all instruments are in accordance with battery testing standards: IEEE 450-2010, IEEE 1188-2005, IEEE 1106-2015, IEC 60896-11/22, and other relevant standards.These units can be used on any type of battery string, such as lead-acid, Li-Ion, Ni-Cd, etc. They test battery strings with voltages in the range of 5,25 – 500 V DC. On the other hand, current up to 250 A can be discharged through the BXL internal structure.The instrument simulates a constant resistance load during the discharge test. Several resistances can be set for different battery nominal voltage levels. This makes BXL extremely flexible in selecting its load capabilities.

  • Power Meters and Calibration Cells

    Sciencetech, Inc.

    The Solar Reference Cell consist of a 20 x 20 mm monocrystalline silicon Photovoltaic Cell encased in a 92 x 70 x 16 mm metal enclosure with a protective quartz window and a temperature sensor. The temperature sensor is a 100 ohm platinum Resistance Temperature Detector (RTD).The Solar Reference Cells come with a Certificate of Calibration and compatible set of connecting cables. The following parameters of the reference cell are certified: Isc, Imax, Voc, Vmax, Pmax, Area, Fill Factor and Efficiency. The certification is accredited by NIST to the ISO-17025 standard and is traceable both to the National Renewable Energy Laboratory (NREL), and to the International System of Units (SI). A compatible cable set is also supplied with each Solar Reference Cell.

  • Surface Resistance System Kit

    PRS-801RM - Prostat Corporation

    - Perform Point-to-Point and Resistance to Ground Measurements from 0.01 Ω to 200 Teraohms- Accuracy of ±2% from 1.00 Ω to 9.99x1010Ω- Measures in accordance with ESD TR53, ANSI/ESD S4.1, ANSI/ESD S7.1, ANSI/ESD STM97.1 and others- Constant Test voltages 10V and 100V meeting ANSI/ESD S20.20- Operates using a Rechargeable Li-ion Battery Pack- Takes Approximately 8,000 Measurements on a Single Charge (480 hours typical)- Stores up to 999 Test Values Into Memory- Compatible with Prostat Connect 2.0 for Downloading into Excel®- Charging and Download via Standard Micro USB Cable- Includes 5lb Conductive Probes and Carrying Case- Certificate of Calibration Traceable to NIST included- 2-year Limited Warranty on Main Instrument

  • Concrete Strength Testers

    Qualitest International Inc.

    This category of products comprises the range of instruments utilized to evaluate construction material strength. The range of instruments is typically considered to be two parts. The first are non-destructive field tests of compressive strength. The second are tensile field tester systems to either determine the tensile strength of an overlay or bond material, or tensile strength of anchors embedded in the concrete. The first group is pure Non-Destructive Testing where the strength of the material is determined by correlation to another parameter more easily available and readily apparent. This is typically the hardness of the concrete or the resistance to penetration by either a pin or probe. The Windsor Probe, Windsor Pin and our line of Rebound Hammers all fall within this category. These are widely used standard tests and as such have seen use throughout the world.

  • Protective Bonding Testers

    RMO-E Series - IBEKO Power AB

    The RMO-E instruments are designed and ideal for testing protective bonding (grounding) of equipment following the standard IEC 61010-1. Also, they can measure the resistance of high, middle and low voltage circuit breakers, high-current bus bar joints, cable splices, and welding joints. The instruments accurately measure not only in factory environments but also in high-induction fields and substations.Both models generate a true DC ripple-free (less than 1 %) current with automatically regulated test ramps. During a test, the protective bonding testers automatically generate increasing current before measuring and decreasing current after the measurement. Consequently, this significantly decreases magnetic transients and ensures great accuracy.These instruments can store up to 500 measurements in the internal memory and have a built-in thermal printer available as an option.DV Win software communicates with the RMO-E earth resistance meter via USB or RS232 interface. It allows a user to run the test remotely from PC, as well as to download test results, analyze and generate fully configurable test reports.The RMO-E series contains two models, RMO60E and RMO100E. The main difference between these two models is in the maximal test current:60 A DC for RMO60E100 A DC for RMO100E

Get Help